RT7514

All rights reserved. This document contains proprietary information of ring&tone and is not to be disclosed or used without the prior written permission of ring&tone.

Due to update and improvement of ring&tone products and technologies, information in this document is subjected to change without notice.

Related products

 
 

Features

  • IEEE802.3at and IEEE802.3afcompliant
  • Maximum 24W output power
  • Input voltage range 36V to 57V
  • Integral high efficiency DC/DC converter.
  • Low output ripple and noise
  • High performance with low price
  • Short-circuit protection
  • Transformer isolation,1500V isolation (input to output)
  • Easy to use, with a minimum number of external components

 

Applications

  • IP Cameras
  • Wireless access point
  • Security and alarm systems
  • VOIP telephone
  • Point of sale network terminal equipment

 

Description

The RT7514 series of modules are designed to extract power from a conventional

twisted pair Category 5 Ethernet cable, conforming to the IEEE 802.3af and IEEE 802.3at    Power-over-Ethernet(PoE) standard.

The RT7514 signature and control circuit provides the PoE compatibility signature and

power classification required by the Power Sourcing Equipment (PSE) before applying up

to 18W power to the port.

The DC/DC converter operates over a wide input voltage range and provides a regulated

output. The DC/DC converter also has built-in short-circuit output protection.

 

Absolute Maximum Ratings

 

Parameter

Symbol

Min

Max

Units

1

DC Supply Voltage

VCC

-0.3

60

V

2

DC Supply Voltage Surge for 1ms

VSURGE

-0.6

80

V

3

Storage Temperature

TS

-40

100

OC

Note 1: Exceeding the above ratings may cause permanent damage to the product. Functional operation under these conditions is not implied. Maximum ratings assume free airflow.

 

Recommended Operating Conditions

 

Parameter

Symbol

Min

Typ

Max

Units

1

Input Supply Voltage 1

VIN

36

48

57

V

2

Under Voltage Lockout

VLOCK

30

 

36

V

3

Operating Temperature 2

TOP

-20

25

70

Ta / OC

Note 1: With minimum load

     2: See Section Operating Temperature Range

      ** Extended use close to, or at the maximum operating temperature can reduce the life time of the device.

 

DC Electrical Characteristics

 

DC Characteristic

Sym

Min

Typ1

Max

Units

Test Comments

1

Nominal Output Voltage

+VDC

4.75

5.0

5.25

V

 

2

Line Regulation

VLINE

 

2

 

%

@ 50% Load

3

Load Regulation

VLOAD

 

2

 

%

@ VIN=48V

4

Output Ripple and Noise

VRN

 

200

 

mVp-p

@ Max load

5

Minimum Load

RLOAD

200

 

 

mA

 

6

Short-Circuit Duration3

TSC

 

 

sec

 

7

Efficiency @ 80% Load

EFF

 

88

 

%

@ 3A load

8

Isolation Voltage (I/O)

VISO

 

1500

 

VPK

Impulse Test

9

Temperature Coefficient

TC

 

0.02

 

%

Per OC

Note 1: Typical figures are at 25°C with a nominal 48V supply and are for design aid only. Not Guaranteed

     2: The output ripple and noise can be reduced with an external filter, see application note.

     3: Continuous short circuit duration is applicable at 25'C ambient temperature in free air. At higher temperatures or with restricted

        airflow (e.g. in a sealed enclosure) the duration will need to be limited to avoid overheating.

 

RT7514 Typical Connection Diagram:

 

TVS Layout description

 

 

RT7514 Product Selector

Part Number

Nominal Output

Maximum Output Power

 

AT-DET putout

Marking

Package

RT7514-5V 

5V 

24W

YES

RT7514

DIP

 

 

 

 

 

 

 

Power Classification

The RT7514 classification is fixed at Class 4, this means that an IEEE802.3at Type 1 or an IEEE802.3af PSE will default to Class 0. However an IEEE802.3at PSE will recognise the Class 4 as a Type 2 PD.

 

AT Detection

The RT7514 has an AT-DET output pin which is used to detect a Two Event Physical Layer classification as described in IEEE802.3at. If required the AT-DET pin can be connected directly to an opto-coupler.

If the RT7514 detects a Two Event Physical Layer classification, the (AT True) switch will close and Opto1 will turn ON. Opto1 will be connected across the isolation barrier and the output collector can be connected to a controller (with a pull-up resistor connected to the controller’s power rail). When Opto1 is ON the collector (output) will be Logic 0, the controller will then know that the PSE is capable of delivering over 15.4W. To complete the protocol the controller should then confirm that it is a Type 2 PD over the Data Link Layer*.

 If the RT7514 detects a Single Event Physical Layer classification, Opto1 will be OFF and the output collector will be Logic 1 (via pull-up resistor). The controller should then assume that the PSE is limited to delivering up to 15.4W.

If the PSE does not support the Physical Layer classification, Opto1 will be OFF. The RT7514 will operate with non IEEE802.3at compliant POE+ PSE’s.

*Note: There are several PSEs (including Cisco) that will only delivery ≤15.4W until they receive Type 2 PD confirmation, over the Data Link Layer.

 

PackageSize: (mm   ±3mm )

 

Pin Description:

Pin

Name

Description

1

-VDC

DC Return. This pin is the return path for the +VDC output.

2

-VDC

DC Return. This pin is the return path for the +VDC output.

3

+VDC

DC Output. This pin provides the regulated output from the DC/DC converter.

4

+VDC

DC Output. This pin provides the regulated output from the DC/DC converter.

5

AT-DET+

AT Detect Output+ 10V voltage.

6

AT-DET-

AT Detect Output-. Integrated series 10 K resistance ,This pin indicates if an IEEE802.3at PSE is supplying power   

7

VIN+

POE Direct Input +. This pin connects to the positive (+) output of the POE input bridge rectifiers.

8

VIN-

POE Direct Input -. This pin connects to the negative (-) output of the POE input bridge rectifiers.

9

CAP-

This pin connects to the capacitance negative.

 

 

 

 

Reliability MTBF:

About the life time ,we design according to the following:

1)  life time of RT7514  : 100,000 hours @ 25°C

 

Isolation (Safetytest items) & test report

This electrical isolation shall withstand at least one of the following electrical strength tests:

RT7514 Test Requested

Test result

a) 1500Vrms at 50Hz to 60Hz for 60s, applied as specified in subclause5.2.2 of IEC60950-1:2001.

Pass

b) 2250Vdc for 60s, applied as specified in subclause5.2.2 of IEC60950-1:2001.

Pass

c) An impulse test consisting of a 1500V, 10/700μs waveform, applied 10 times, with a 60s interval between pulses. The shape of the impulses shall be 10/700μs (10μs virtual front time, 700μsvirtual time of half value), as defined in IEC60950-1:2001 Annex N.

Pass

 

Operating tempprofile

 

Mechanical / Environmental Performance data

Mechanical / Environmental Performance data

 

Item

Requirement and Standard

1

Resistance to Wave Soldering Heat

max Preheat Temp range & time 120 ℃ / 180S

max soldering temp &time:265 ℃ / 4S

2

Solder ability

Solder able area shall have minimum of 95% solder coverage.

And then into solder bath,Temperature at 245 ±5 ℃   , for 4-5sec.

3

Hand Soldering Temperature Resistance

T  > =350 ℃   , 3sec at least.

4

Thermal Shock

subject to follow condition for 5 cycles.1 cycles:

-55 ℃    , 30 minutes

+85 ℃    , 30 minutes

5

Humidity(Temp Cycling)

less than 95% (non-condensing) ( -20 to 70 ℃)

6

Temperature Life

temperature life at 85℃     for 96 hours.

7

Salt Spray

connectors to 5% salt-solution concentration, 35 ℃

Gold flash for 8 hours there will be no change in the gold layer

 

Packaging type & Quantity

1.EPE Packaging,                 2.Blister Packaging,

40pcs/ dish                        50pcs/ dish    

400pcs/box                       500pcs/box